Output Torque
Calculate the valve torque: Based on the butterfly valve size, pressure rating, medium characteristics, and specific requirements of the piping system, calculate the torque required to open and close the butterfly valve.
Allow for a safety factor: To ensure that the electric actuator can reliably drive the butterfly valve, a certain safety factor should be reserved based on the calculated torque. The safety factor is usually between 1.2 and 1.5.
Control Mode
On/Off type: Suitable for applications where the butterfly valve only needs to be fully open or fully closed, such as in simple fluid shutoff systems where precise flow regulation is not required and only the opening and closing of the pipeline need to be controlled. An on/off electric actuator can be selected.
Modulating type: When the opening of the butterfly valve needs to be precisely adjusted to control parameters such as fluid flow and pressure, a modulating electric actuator should be selected.
Smart type: Smart electric actuators have functions such as self-diagnosis, remote communication, and data recording, making them suitable for systems with high automation requirements that need centralized monitoring and management. For example, in butterfly valve control at large water treatment plants, smart electric actuators can enable remote monitoring and fault diagnosis.
Power Supply Requirements
Voltage rating: Select an appropriate voltage rating based on the on-site power supply conditions. Common voltages include 220 V and 380 V. In general industrial applications, 380 V power is commonly used, while some residential or small-scale systems may use 220 V power.
Power supply type: Both AC and DC power supply types are available. AC power is widely used and provides stable power supply. DC power is suitable for applications with high requirements for power stability, special explosion-proof requirements, or integration with DC control systems, such as butterfly valve control on ships powered by DC power or in explosion-proof areas.
Actuation Time
Determine based on process requirements: Different process flows have different requirements for the opening and closing speed of butterfly valves. For example, in some emergency shutoff systems, the butterfly valve is required to close quickly within a short period to prevent accidents from escalating, so an electric actuator with a short actuation time should be selected. In systems where flow regulation requirements are not high and slow opening and closing are acceptable, the requirements for actuation time are relatively low.
Consider the actuator type: Different types of electric actuators have different actuation times. Generally, linear electric actuators have relatively long actuation times, while angular electric actuators have shorter actuation times. For butterfly valves, angular electric actuators are usually used, with actuation times generally ranging from a few seconds to several tens of seconds, and the selection can be made according to specific process requirements.
Protection Rating
Assess environmental conditions: Determine the required protection rating of the electric actuator based on the environmental conditions at the installation location of the butterfly valve, such as whether the environment is humid, dusty, or contains corrosive gases. For example, in outdoor wastewater treatment plants, electric actuators may be exposed to rainwater, dust, and other corrosive factors, so products with a higher protection rating should be selected.
Other Factors
Installation method: Select an appropriate electric actuator installation method, such as flange connection or shaft sleeve connection, based on the installation position and spatial layout of the butterfly valve. Ensure that the connection between the electric actuator and the butterfly valve is secure, easy to install, and convenient for later maintenance and inspection.